According to the transient characteristic and tabulated values of thermal resistances for high-frequency impulse voltage converters LM 2676, a thermoelectric model was obtained in the form of a Foster circuit, in which the electrical transient process coincides numerically with the transient thermal characteristic. With the help of the obtained thermoelectric model, the process of temperature change with a short-term increase in load and power loss is investigated.
thermal resistance, thermoelectric model, Foster circuit
1. Niss, V.S. Ocenka teplovyh parametrov moschnyh bipolyarnyh tranzistorov metodom teplovoy relaksacionnoy differencial'noy spektrometrii/ V.S. Niss, O.S. Vas'kov, A.S. Turcevich, A.F. Kerencev, V.K. Kononenko //Pribory i metody izmereniy. - 2015. - T. 6. - № 2. - S. 249-256.
2. Smirnov, V.I. Metod izmereniya komponent teplovogo soprotivleniya poluprovodnikovyh priborov i ego prakticheskaya realizaciya [i dr.] /V.I. Smirnov, A.A. Gavrikov, A.M. Shorin // Avtomatizaciya processov upravleniya. - 2017. - № 2.
3. Gavrikov, A.A. Izmeritel' teplovogo impedansa poluprovodnikovyh diodov s shirotno-impul'snoy modulyaciey greyuschey moschnosti / V.A. Sergeev, V.I. Smirnov, A.A. Gavrikov, M. L. Kontorovich // Promyshlennye ASU i kontrollery. - 2010. - №3. - S.45-47.
4. JEDEC JESD51-14 standard. Transient Dual Interface Test Method for the Measurement of the Thermal Resistance Junction to Case of Semiconductor Devices with Heat Flow through a Single Path.
5. T3Ster - Thermal Transient Tester. - URL:https://www.mentor.com/micred/t3ster.